Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
PLoS One ; 17(6): e0268382, 2022.
Article in English | MEDLINE | ID: covidwho-1875091

ABSTRACT

BACKGROUND: Throughout the COVID-19 pandemic, testing individuals remains a key action. One approach to rapid testing is to consider the olfactory capacities of trained detection dogs. METHODS: Prospective cohort study in two community COVID-19 screening centers. Two nasopharyngeal swabs (NPS), one saliva and one sweat samples were simultaneously collected. The dog handlers (and the dogs…) were blinded with regards to the Covid status. The diagnostic accuracy of non-invasive detection of SARS-CoV-2 infection by canine olfaction was assessed as compared to nasopharyngeal RT-PCR as the reference standard, saliva RT-PCR and nasopharyngeal antigen testing. RESULTS: 335 ambulatory adults (143 symptomatic and 192 asymptomatic) were included. Overall, 109/335 participants tested positive on nasopharyngeal RT-PCR either in symptomatic (78/143) or in asymptomatic participants (31/192). The overall sensitivity of canine detection was 97% (95% CI, 92 to 99) and even reached 100% (95% CI, 89 to 100) in asymptomatic individuals compared to NPS RT-PCR. The specificity was 91% (95% CI, 72 to 91), reaching 94% (95% CI, 90 to 97) for asymptomatic individuals. The sensitivity of canine detection was higher than that of nasopharyngeal antigen testing (97% CI: 91 to 99 versus 84% CI: 74 to 90, p = 0.006), but the specificity was lower (90% CI: 84 to 95 versus 97% CI: 93 to 99, p = 0.016). CONCLUSIONS: Non-invasive detection of SARS-CoV-2 infection by canine olfaction could be one alternative to NPS RT-PCR when it is necessary to obtain a result very quickly according to the same indications as antigenic tests in the context of mass screening.


Subject(s)
COVID-19 , Animals , COVID-19/diagnosis , COVID-19/veterinary , Dogs , Humans , Pandemics , Prospective Studies , SARS-CoV-2/genetics , Smell
2.
Lancet Infect Dis ; 22(3): 341-348, 2022 03.
Article in English | MEDLINE | ID: covidwho-1537188

ABSTRACT

BACKGROUND: Mass indoor gatherings were banned in early 2020 to prevent the spread of SARS-CoV-2. We aimed to assess, under controlled conditions, whether infection rates among attendees at a large, indoor gathering event would be similar to those in non-attendees, given implementation of a comprehensive prevention strategy including antigen-screening within 3 days, medical mask wearing, and optimised ventilation. METHODS: The non-inferiority, prospective, open-label, randomised, controlled SPRING trial was done on attendees at a live indoor concert held in the Accor Arena on May 29, 2021 in Paris, France. Participants, aged 18-45 years, recruited via a dedicated website, had no comorbidities, COVID-19 symptoms, or recent case contact, and had had a negative rapid antigen diagnostic test within 3 days before the concert. Participants were randomly allocated in a 2:1 ratio to the experimental group (attendees) or to the control group (non-attendees). The allocation sequence was computer-generated by means of permuted blocks of sizes three, six, or nine, with no stratification. The primary outcome measure was the number of patients who were SARS-CoV-2-positive by RT-PCR test on self-collected saliva 7 days post-gathering in the per-protocol population (non-inferiority margin <0·35%). This trial is registered with ClinicalTrials.gov, NCT04872075. FINDINGS: Between May 11 and 25, 2021, 18 845 individuals registered on the dedicated website, and 10 953 were randomly selected for a pre-enrolment on-site visit. Among 6968 who kept the appointment and were screened, 6678 participants were randomly assigned (4451 were assigned to be attendees and 2227 to be non-attendees; median age 28 years; 59% women); 88% (3917) of attendees and 87% (1947) of non-attendees complied with follow-up requirements. The day 7 RT-PCR was positive for eight of the 3917 attendees (observed incidence, 0·20%; 95% CI 0·09-0·40) and three of the 1947 non-attendees (0·15%; 0·03-0·45; absolute difference, 95% CI -0·26% to 0·28%), findings that met the non-inferiority criterion for the primary endpoint. INTERPRETATION: Participation in a large, indoor, live gathering without physical distancing was not associated with increased SARS-CoV-2-transmission risk, provided a comprehensive preventive intervention was implemented. FUNDING: French Ministry of Health. TRANSLATION: For the French translation of the abstract see Supplementary Materials section.


Subject(s)
COVID-19 , Mass Gatherings , Mass Screening , SARS-CoV-2/isolation & purification , Adult , COVID-19/prevention & control , COVID-19/therapy , Female , France , Humans , Male , Prospective Studies , Saliva/cytology
3.
Sci Rep ; 11(1): 21126, 2021 10 26.
Article in English | MEDLINE | ID: covidwho-1493210

ABSTRACT

Rapid identification of SARS-CoV-2-infected individuals is a cornerstone for the control of virus spread. The sensitivity of SARS-CoV-2 RNA detection by RT-PCR is similar in saliva and nasopharyngeal swabs. Rapid molecular point-of-care tests in saliva could facilitate, broaden and speed up the diagnosis. We conducted a prospective study in two community COVID-19 screening centers to evaluate the performances of a CE-marked RT-LAMP assay (EasyCoV) designed for the detection of SARS-CoV2 RNA from fresh saliva samples, compared to nasopharyngeal RT-PCR, to saliva RT-PCR and to nasopharyngeal antigen testing. Overall, 117 of the 1718 participants (7%) tested positive with nasopharyngeal RT-PCR. Compared to nasopharyngeal RT-PCR, the sensitivity and specificity of the RT-LAMP assay in saliva were 34% and 97%, respectively. The Ct values of nasopharyngeal RT-PCR were significantly lower in the 40 true positive subjects with saliva RT-LAMP (Ct 25.9) than in the 48 false negative subjects with saliva RT-LAMP (Ct 28.4) (p = 0.028). Considering six alternate criteria for reference tests, including saliva RT-PCR and nasopharyngeal antigen, the sensitivity of saliva RT-LAMP ranged between 27 and 44%. The detection of SARS-CoV-2 in crude saliva samples with an RT-LAMP assay had a lower sensitivity than nasopharyngeal RT-PCR, saliva RT-PCR and nasopharyngeal antigen testing.Registration number: NCT04578509.


Subject(s)
Ambulatory Care/methods , COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , COVID-19/metabolism , SARS-CoV-2 , Saliva/metabolism , Adult , Diagnostic Tests, Routine , False Negative Reactions , False Positive Reactions , Female , Humans , Male , Middle Aged , Molecular Diagnostic Techniques , Molecular Medicine , Nasopharynx/virology , Nucleic Acid Amplification Techniques , Point-of-Care Systems , Point-of-Care Testing , Prospective Studies , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Reproducibility of Results , Sensitivity and Specificity
4.
Eur J Clin Microbiol Infect Dis ; 40(11): 2379-2388, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1338227

ABSTRACT

Nasopharyngeal sampling for nucleic acid amplification testing (NAAT) is the standard diagnostic test of coronavirus disease 2019. Our objectives were to assess, in real-life conditions, the diagnostic accuracy of a nasopharyngeal point-of-care antigen (Ag) test and of saliva NAAT for detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in ambulatory care. This was a prospective cohort study from 19 October through 18 December 2020 in two community COVID-19 screening centers in Paris, France. Two nasopharyngeal swabs and one saliva sample were simultaneously collected. Diagnostic accuracies of nasopharyngeal Ag testing and of three saliva NAAT methods were assessed as compared to nasopharyngeal NAAT. A total of 1452 ambulatory children and adults were included. Overall, 129/1443 (9%) participants tested positive on nasopharyngeal NAAT (102/564 [18%] in symptomatic and 27/879 [3%] in asymptomatic participants). Sensitivity was 94%, 23%, 96%, and 94% for the three different protocols of saliva NAAT and for the nasopharyngeal Ag test, respectively. Estimates of specificity were above 95% for all methods. Diagnostic accuracy was similar in symptomatic and asymptomatic individuals. Diagnostic accuracy of nasopharyngeal Ag testing and of saliva NAAT is similar to that of nasopharyngeal NAAT, subject to compliance with specific protocols for saliva. Registration number: NCT04578509.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnostic imaging , Nasopharynx/virology , SARS-CoV-2/isolation & purification , Saliva/virology , Specimen Handling/methods , Adult , Cohort Studies , Female , Humans , Male , Mass Screening , Middle Aged , Nucleic Acid Amplification Techniques/methods , Paris , Point-of-Care Testing , Prospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL